Part Number Hot Search : 
100RJ TE156 KP120 EL2020CN MC33989 332M0 ON2005 AO4290A
Product Description
Full Text Search
 

To Download NJU3714A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NJU3714A
12-BIT SERIAL TO PARALLEL CONVERTER
GENERAL DESCRIPTION
The NJU3714A is a 12-bit serial to parallel converter especially applying to MPU outport expander. It can operate from 2.4V to 5.5V. The effective outport assignment of MPU is available as the connection between NJU3714A and MPU using only 4 lines. The serial data synchronizing with 5MHz or more clock can be input to the serial data input terminal and the data are output from parallel output buffer through serial in parallel out shift register and parallel data latches. Furthermore, the NJU3714A outputs the serial data from SO terminal through the shift register. Therefore, it connects with other SIPO ICs like as NJU3711A in cascade for expanding the parallel conversion outputs. The hysteresis input circuit realizes wide noise margin and the high drive-ability output buffer (25mA) can drive LED directly.
PACKAGE OUTLINE
NJU3714AV
FEATURES
12-Bit Serial In Parallel Out Cascade Connection Hysteresis Input 0.5V typ at 5V Operating Voltage 2.4 to 5.5V Maximum Operating Frequency 5MHz and more Output Current 25mA at 5V, 5mA at 3V C-MOS Technology Package Outline SSOP20
PIN CONFIGURATION
P5 P6 P7 P8 VSS P9 P10 P11 P12 SO 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 VDD P4 P3 P2 P1 VSS CLR STB CLK DATA
NJU3714AV
BLOCK DIAGRAM
DATA Shift Register Latch Circuit CLK
P1 P2 P3
P11 P12 SO STB CLR Controller Circuit
Ver.2003-11-18
-1-
NJU3714A
TERMINAL DESCRIPTION
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SYMBOL P5 P6 P7 P8 VSS P9 P10 P11 P12 SO DATA CLK STB CLR VSS P1 P2 P3 P4 VDD I/O O O O O O O O O O I I I I O O O O FUNCTION Parallel Conversion Data Output Terminals GND Parallel Conversion Data Output Terminals Serial Data Output Terminal Serial Data Input Terminal Clock Signal Input Terminal Strobe Signal Input Terminal Clear Signal Input Terminal GND Parallel Conversion Data Output Terminals Power Supply Terminal (2.4 to 5.5V)
-2-
Ver.2003-11-18
NJU3714A NJU3555
FUNCTIONAL DESCRIPTION
(1) Reset When the "L" level is input to the CLR terminal, all latches are reset and all of parallel conversion output are "L" level. Normally, the CLR terminal should be "H" level. (2) Data Transmission In the STB terminal is "H" level and the clock signals are inputted to the CLK terminal, the serial data into the DATA terminal are shifted in the shift register synchronizing at a rising edge of the clock signal. When the STB terminal is changed to "L" level, the data in the shift register are transferred to the latches. Even if the STB terminal is "L" level, the input clock signal shifts the data in the shift register, therefore, the clock signal should be controlled for data order.
(3) Cascade Connection
The serial data input from DATA terminal is output from the SO terminal through internal shift register unrelated with the CLR and STB status. Furthermore, the 4 input circuits provide a hysteresis characteristics using the schmitt trigger structure to protect the noise.
CLK X STB X H L H L H CLR L H OPERATION
All of latches are reset (the data in the shift register is no change). All of parallel conversion outputs are "L". The serial data into the DATA terminal are inputted to the shift register. In this stage, the data in the latch is not changed. The data in the shift register is transferred to the latch. And the data in the latch is output from the parallel conversion output terminals. When the clock signal is inputted into the CLK terminal in state of the STB="L" and CLR="H", the data is shifted in the shift register and latched data is also changed in accordance with the shift register.
Note 1) X: Don't care
Ver.2003-11-18
-3-
NJU3714A
TIMING CHART
CLK CLR STB DATA P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 SO
-4-
Ver.2003-11-18
NJU3714A NJU3555
ABSOLUTE MAXIMUM RATINGS
(Ta=25C) PARAMETER Supply Voltage Range Input Voltage Range Output Voltage Range Output Current Output Short Current
(SO Terminal)
(Note 5)
SYMBOL VDD VI VO IO IOS
RATINGS -0.5 ~ +7.0 VSS-0.5 ~ VDD+0.5 VSS-0.5 ~ VDD+0.5 25 VO=7V, VI=0V VO=0V, VI=7V VO=7V, VI=0V VO=0V, VI=7V 10 (max) -10 (max) 20 (max) -20 (max)
UNIT V V V mA mA
Output Short Current
(P1~P8 Terminals)
(Note 5)
IOSD PD Topr Tstg
mA mW C C
Power Dissipation
(Note 6)
570 (SSOP) -25 ~ +85 -65 ~+150
Operating Temperature Range Storage Temperature Range
Note 2) All voltage are relative to VSS=0V reference. Note 3) Do not exceed the absolute maximum ratings, otherwise the stress may cause a permanent damage to the IC. It is also Note 4) Note 5) Note 6)
recommended that the IC be used in the range specified in the DC electrical characteristics, or the electrical stress may cause malfunctions and impact on the reliability. To stabilize the IC operation, place decoupling capacitor between VDD and VSS. VDD=7V, VSS=0V, less than 1 second per pin. Mounted on a PCB.
DC ELECTRICAL CHARACTERISTICS
PARAMETER Operating Voltage Operating Current High-level Output Voltage Low-level Output Voltage High-level Input Voltage Low-level Input Voltage Input Leakage Current
SYMBOL
(VDD=2.4~5.5V, VSS=0V, Ta=25C, unless otherwise noted) CONDITION MIN TYP MAX UNIT 2.4 VIH=VDD, VIL=VSS IOH=-0.4mA IOL=+3.2mA
SO Terminal
VDD IDDS VOH VOL VIH VIL ILI VI=0~VDD
IOH=-25mA
-
5.5 0.1 VDD 0.4 VDD 0.3VDD 10 VDD VDD VDD VDD 1.5 0.8 0.4 0.5
V mA V V V V A
VDD-0.4 VSS 0.7VDD VSS -10 VDD-1.5
P1~P12 Terminals
High-level Output Voltage
(Note 7)
VOHD
VDD=5V
IOH=-15mA IOH=-10mA
VDD-1.0 VDD-0.5 VDD-0.5 VSS
V
VDD=3V
IOH=-5mA IOL=+25mA
Low-level Output Voltage
(Note 7)
VOLD
VDD=5V
IOL=+15mA IOL=+10mA
P1~P12 Terminals
VSS VSS VSS
V
VDD=3V
operation should be required.
IOL=+5mA
Note 7) Specified value represent output current per pin. When use, total current consideration and less than power dissipation in rating
Ver.2003-11-18
-5-
NJU3714A
SWITCHING CHARACTERISTICS
PARAMETER Set-Up Time Hold Time Set-Up Time Hold Time SYMBOL tSD tHD tSSTB tHSTB tpd O Output Delay Time tpd PCK tpd PSTB tpd PCLR
Maximum Operating Frequency
(VDD=2.4~5.5V, VSS=0V, Ta=25C, unless otherwise noted) CONDITION MIN TYP MAX UNIT DATA-CLK CLK-DATA STB-CLK CLK-STB CLK-SO CLK-P1~P12 STB-P1~P12 CLR-P1~P12 20 20 30 30 5 70 100 80 80 ns ns ns ns ns ns ns ns MHz
fMAX
Note 8) COUT=50pF
-6-
Ver.2003-11-18
NJU3714A NJU3555
SWITCHING CHARACTERISTICS TEST WAVEFORM
fMAX CLK tSD DATA tHD STB tHSTB tSSTB
CLK tpd O SO
CLK tpd PCK L STB
P1~P12
CLK
H
STB tpd PSTB P1~P12
CLR DATA tpd PCLR
H
P1~P12
Ver.2003-11-18
-7-
NJU3714A
APPLICATION CIRCUIT (1)
MPU
P2 DATA CLK STB CLR SO
P1
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
NJU3714A
APPLICATION CIRCUIT (2) (Combined with NJU3711A)
MPU
P2 DATA CLK STB CLR SO
P1
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
NJU3714A
DATA CLK STB CLR
NJU3711A
P1 P2 P3 P4 P5 P6 P7 P8
MOTOR DRIVER
M
[CAUTION] The specifications on this databook are only given for information , without any guarantee as regards either mistakes or omissions. The application circuits in this databook are described only to show representative usages of the product and not intended for the guarantee or permission of any right including the industrial rights.
-8-
Ver.2003-11-18


▲Up To Search▲   

 
Price & Availability of NJU3714A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X